Proc Sheet 4 01
myX3-2
REMOVING/ REPLACING THE DATA/ AUDIO/
CHARGE CONNECTOR
1/3
Ref. SCT U38 SSC DTS 0014 – Index B - March 30, 2004 Page 5-43
Notice: The handsets requiring the replacement of system connectors cannot be repaired under
Sagem warranty.
The eventual deterioration of the board due to a bad replacement of the connector fall under the
Repair Centre responsibility.
- Replacement procedure of DATA/ AUDIO/ CHARGE connector
1-Disassemble the handset Proc 1 04
2-Replace the defective connector (see below) Ref 18 598 906-8
3 - Replace the electronic board in the mobile phone Proc 1 04
4 -To test the replacement of the connector, it is necessary to:
a) Connect the mobile phone on SMT maintenance software (test Sheet 01)
b) Make real calls with a pedestrian handsfree Kit Reference :23 812 517-0
c) Test the charge of mobile phone
5 - Standard test after repair